Suitable for in-line inspection of the residual bone fragments in meat processing, for instance, inspecting residual collarbones, shoulder blades in chicken.
Model | TXR-4080BDE | |||
---|---|---|---|---|
X-ray Generator | MAX. 80kV, 350W | |||
Inspection Width | 400mm | |||
Inspection Height | 100mm | |||
Best Inspection Sensitivity (Without Product) | Stainless steel ball Ø0.3mm Stainless steel wire Ø0.2*2mm Glass/Ceramic ball Ø1.0mm |
|||
Conveyor Speed | 10-40m/min | |||
Operation System | Windows 7 | |||
Protection Method | Soft curtain | |||
X-ray Leakage | < 1 μSv/h (CE Standard) | |||
IP Rate | IP66 (Under belt) | |||
Working Environment | Temperature: -10~40°C | |||
Humidity: 30-90%, no dew | ||||
Cooling method | Industrial air conditioning | |||
Rejecter Mode | Sound and light alarm, belt stop (Rejecter optional) | |||
Air Pressure | 0.8 Mpa | |||
Power Supply | 1.5kVA | |||
Main Material | SUS304 | |||
Surface Treatment | Mirror polish / Sand blasting |
Note:
The technical parameter above namely is the result of sensitivity by inspecting only the test sample on the belt. The actual sensitivity would be affected according to the products being inspected.